License Method

EPA 608 Core Practice Test: Free, With Answers

Last checked October 20, 2026

Core is the one section everyone takes. Practice it here for free.

Question 1 of 5

Which element released from CFC molecules in the stratosphere is mainly responsible for destroying ozone?

Question 2 of 5

Why can a small amount of chlorine cause large ozone losses?

Question 3 of 5

Which is a recognized health effect of increased UV-B radiation reaching the ground because of ozone depletion?

Question 4 of 5

Ozone depletion potential (ODP) values are measured relative to which refrigerant, which is assigned an ODP of 1.0?

Question 5 of 5

HFCs do not deplete ozone, but many are still regulated because they:

Why Core comes first

Every EPA 608 certification includes Core. A Type I, II, III or Universal card is only issued if you pass it (40 CFR Part 82, Appendix D).

The exam gives you 25 Core questions. You need 70%, which means 18 correct.

What Core covers

Core is the shared ground for every technician. EPA's Core topic list includes (EPA test topics):

  • Environmental impacts. How chlorine from CFCs and HCFCs destroys stratospheric ozone, and how ODP compares across CFCs, HCFCs and HFCs.
  • Clean Air Act and Montreal Protocol. Phaseout dates, the venting ban and penalties.
  • Section 608 rules. Pressure classes, certified recovery equipment, the AHRI 700 standard for reclaimed refrigerant, and the sales restriction (40 CFR 82.154(c)).
  • Substitutes and oils. There are no true drop-ins. Blends can fractionate, and oils must match the refrigerant.
  • Refrigeration basics. Refrigerant states around the cycle, and gauges.
  • Recovery and dehydration. Never mix refrigerants. Know what speeds recovery, and evacuate to remove air and moisture.
  • Safety and shipping. Oxygen deprivation, frostbite, PPE, nitrogen with a regulator, the 80% fill limit and cylinder labels.

Recover, recycle, reclaim

These three words show up on almost every Core test.

  • Recover: remove refrigerant from a system and store it in a container.
  • Recycle: clean refrigerant for reuse, usually on site, by separating oil and passing it through filter-driers.
  • Reclaim: reprocess refrigerant to the purity of new product, verified by lab analysis.

A common question asks what must happen before used refrigerant is sold to someone else. With a few narrow exceptions, the answer is reclaim, by a certified reclaimer (40 CFR 82.152, 82.154(d)).

One trap to avoid

Some programs offer Core as an open-book test bundled with Type I. EPA says an open-book Core score can't be used toward Universal. For Universal, Core has to be taken as a proctored exam (EPA certification requirements).

If you plan to work on split systems or chillers later, take Core proctored from the start.

How our Core test works

  • One question per screen, built for your phone
  • Instant feedback, an explanation and a strategy tip
  • The rule cited under every answer
  • Progress saved on your device, with no account needed

Use practice mode to learn. Switch to the timed 25-question test when you're scoring 18 or better.

A study plan that fits a week

  1. Day 1: Take the full Core test cold. Note your weak topics.
  2. Days 2 to 4: Read those topics in the study guide.
  3. Day 5: Retry the questions you missed.
  4. Day 6: Take a timed test.
  5. Day 7: Rest, then book your proctored exam.

Start the full test

Take the free Core test

80 free questions. No signup.

Sources