License Method

EPA 608 Type 1 Practice Test (Small Appliances)

Last checked October 20, 2026

Type I covers small appliances such as refrigerators, freezers and window units. Try three sample questions now.

Question 1 of 3

Under the Section 608 rules, which description defines a "small appliance"?

Question 2 of 3

Which of these appliances is NOT a small appliance under the Section 608 definition?

Question 3 of 3

A factory-sealed commercial reach-in cooler holds 6 pounds of R-134a, a medium-pressure refrigerant. What certification does a technician need to service its sealed system?

What counts as a small appliance

EPA's definition has two parts. The appliance is fully manufactured, charged and hermetically sealed in a factory, and it holds 5 pounds or less of refrigerant (40 CFR 82.152).

If either part fails, it isn't Type I work. A field-piped split system is Type II, even if its charge is small.

The recovery numbers to know

Before you open or dispose of a small appliance, you recover the refrigerant with certified equipment. EPA gives three ways to meet the requirement (40 CFR 82.156(b)):

Situation Requirement
Recovery equipment made before Nov 15, 1993 Recover 80% of the refrigerant
Equipment made on or after Nov 15, 1993, compressor working Recover 90%
Equipment made on or after Nov 15, 1993, compressor not working Recover 80%
Any of the above, as an alternative Evacuate to 4 in. Hg vacuum

Questions often hide the compressor's condition in the stem. Read for it.

Other Type I topics

EPA's Type 1 topic list adds these (EPA test topics):

  • System-dependent ("passive") recovery. This uses the appliance's own compressor or pressure. It's allowed on small appliances, but not on systems over 15 lb unless it's a permanent pump-out unit (40 CFR 82.156(e)). Run the compressor if it works.
  • Dead compressors. Install access valves on both the high and low sides. Heat and tap the compressor to free trapped refrigerant.
  • Access fittings. Remove solderless access fittings when you finish the job.
  • Identifying refrigerant. Compare pressure and temperature to name the refrigerant and spot non-condensables.
  • Safety. Refrigerants exposed to high heat or flame break down into dangerous products.
  • Disposal. The final processor in the disposal chain must recover the refrigerant, or verify that it was removed, usually with a signed statement (40 CFR 82.155).

Mail-in, open-book or proctored

Type I is the one section that some programs offer as a mail-in test. EPA's rules set a higher bar for that format: 84%, or 21 of 25, instead of 70%. A mail-in Type I can't be counted toward Universal (40 CFR Part 82, Appendix D).

If you might want Type II or III later, consider taking Type I proctored along with a proctored Core.

How to practice

  1. Pass the free Core test first, since every card requires Core.
  2. Try the Type I samples above.
  3. Unlock the full Type I bank and the Universal mock exam with the $19 one-time Universal pass.

The pass covers Core plus Types I, II and III. There's no subscription.

Universal pass

$19 one-time
  • Full practice for Types I, II and III, plus free Core
  • Timed 100-question Universal mock
  • Retry lists, strategy tips and a citation on every question
Get the Universal pass · $19TEST MODE

Compare plans

Sources